Well Test/Early Production Facility Equipment
Flare Knockout Drum

Equipment Details
DESCRIPTION | Vessel Orientation: Horizontal | |||
Main Vessel Dimensions: 48” OD x 15’ S/S Length | ||||
Phase: 2 | ||||
Maximum Allowable working Pressure | 125Psig | |||
Maximum Design Temperature | 100oF | |||
Minimum Design Temperatures | -20oF@125Psig | |||
Liquid Handling Capacity Per Unit | 12087BPD | |||
Gas Handling Capacity | 60MMSCFD @125PSIG | |||
CONNECTION NOZZLES SPECIFICATION | ||||
Inlet Nozzle | 6 inches RFWN x #150 | |||
Gas Outlet | 4 inches RFWN x #150 | |||
Liquid outlet | 3 inches RFWN x #150 | |||
Drain Outlet | 2 inches RFWN x #150 | |||
Manway | 24 inches RFWN x #150 |
MATERIALS OF CONSTRUCTION | Shell: | SA-516-70 | ||
Elliptical Head | SA-516-70 | |||
Nozzles: | SA-105,SA-350-LF2 | |||
Skid (Structural Components | A572 Gr-50, A-500 Gr-B Sa-516-70, A36 | |||
INSTRUMENTRUMENTATION & PNEUMATIC CONTROL SYSTEM: | ||||
SECTIONS | PRESSURE | TEMPERATURE | ||
GAUGES | Gas | NO | No | |
Liquid | No | No | ||
SDV | NO | SDV Pneumatic Instrument | Yes | |
Liquid LCV | Yes | LC Pneumatic Instrument | Yes | |
Gas PCV | No | Gas PC Pneumatic Instrument | Yes | |
Condensate Transfer Pump | Yes | Pumps Pneumatic control Sys | Yes | |
PSV | Yes | |||
2 Sight Glasses | Yes | |||
Manual Valves | Installed Accordingly | |||
Strainer | Installed Accordingly | |||
APPLICABLE STANDARDS: | ASME SECTION VIII DIVISION 1, NACE MR0175 API 6A, API 6D, ANSI B31.3, API 12J CLASS 1 DIVISION (UL, EXP) |